OWNER‘S MANUALLINEAR PRECISION POWER AMP
10MAINS OPERATION & RESULTING TEMPERATURE CL1600Umains [V]Imains [A]Pmains[W]Pout [W]Pd (6)[W]BTU/hr(4)idle230V0,565-65220Max. Output Power @ 8Ω(1
SPECIFICATIONS31CL800CL1200CL1600CL2000Load Impedance 2 Ω4 Ω8 Ω2 Ω4 Ω8 Ω2 Ω4 Ω8 Ω2 Ω4 Ω8 ΩMax. MidbandOutput PowerTHD = 1%, 1kHz , Dual Channel600W400
BLOCK DIAGRAM32
ABMESSUNGEN / DIMENSIONSABMESSUNGEN / DIMENSIONS (in mm)33
NOTES34
NOTES35
USA Telex Communications Inc., 12000 Portland Ave. South, Burnsville, MN 55337, Phone: +1 952-884-4051, FAX: +1 952-884-0043GermanyEVI AUDIO GmbH, Hir
CONTENTSIMPORTANT SAFETY INSTRUCTIONS ... 3IMPORTANT SERVICE INSTRUCTIONS ... 3DESCRIPTION...
3The lightning ash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “danger
Congratulations! With buying a DYNACORD CL-SERIES power ampli er you have chosen an appli-ance that employs most advanced technology.CL-Series power
UNPACKING & WARRANTYCarefully open the packaging and take out the power ampli er. Next to the power ampli er itself, the package also includes t
FRONT PANELThis indicator lights when the power ampli er has been switched on. Causes for the POWER-indicator not lighting are: the appliance is not
INPUT A / INPUT B NF-CONNECTION CORDSChoosing high-quality balanced cables (two conductors for the audio signal plus seperate shielding mesh) with XL
REAR PANELPower amp output connection for the two channels A (left) and B (right) is provided via SPEAKON-type output connectors. A plastic cover to p
MAINS OPERATION & RESULTING TEMPERATURE MAINS OPERATION & RESULTING TEMPERATUREThe following tables allow determining power supply and cabling